MSG_Exception: Event Handler Messages
FlashCONNECT Administrator’s Guide 193
w3Pipe::StartConnect(): connect(), errorcode
w3Pipe::StartConnect(): CreateEvent()
w3Pipe::StartConnect(): CreateFile(), errorcode
w3Pipe::StartRead() buf!=NULL, bufsz<1
w3Pipe::StartRead() ERROR_PIPE_NOT_CONNECTED, possible
Flash/NonFlash compile mismatch", errorcode
Meaning: Failure during socket connection under UNIX.
Severity: FCService will fail.
Action: Check errorcode and resolve underlying problem.
Meaning: Failure to create an event during socket connection start-up under
Windows.
Severity: FCService will fail.
Action: Check errorcode and resolve underlying problem.
Meaning: Unable to create a pipe file under Windows.
Severity: FCService will fail.
Action: Check errorcode and resolve underlying problem.
Meaning: Internal error trying to create a second buffer during read from pipe!
Severity: FCService will fail.
Action: Contact Raining Data Customer Support.
Meaning: For D3: It’s likely that the application has aborted. This may be due to
Flash and non-Flash compiled modules being mixed.
For mvBase: It’s likely that the application has aborted.
Severity: Page will fail.
Action: For D3: Ensure that all applications are Flash-compiled and running
properly.
For mvBase: Ensure that all applications are running properly.